–138–
EC65 SELF-CONTAINED AIR-COOLED — STANDARD CUBE
NOTE: These characteristics may vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°C
Freeze Time
Harvest
Time
Times in minutes.
Water Temperature °C
10 15 20 25 30 35 40
10 21.2-23.8
3.0 min.
15 23.4-26.4 25.0-28.1
20 25.6-28.8 27.4-30.8 29.6-33.2 32.0-35.8 34.8-38.9
25 27.4-30.8 32.0-35.8 32.0-35.8 34.8-38.9 38.1-42.6
30 30.3-34.0 32.9-36.8 35.8-40.1 39.3-43.9 43.4-48.5 48.4-54.1 54.7-61.0
35 39.3-43.9 43.4-48.5 48.4-54.1 54.7-61.0 65.8-73.3
40 57.1-63.7 65.8-73.3 77.3-86.1
45 69.2-77.1 82.1-91.4 100.4-111.7