–117–
EC40 SELF-CONTAINED AIR-COOLED — LARGE CUBE
NOTE: These characteristics may vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Continued on next page …
Air Temp.
Entering
Condenser
°C
Freeze Time
Harvest
Time
Times in minutes.
Water Temperature °C
10 15 20 25 30 35 40
10 28.4-30.4
3.5 min.
15 30.2-32.4 32.2-34.5
20 32.9-35.3 34.5-36.9 37.1-39.7 39.0-41.8 41.1-44.0
25 35.3-37.8 37.1-39.7 40.1-42.9 43.5-46.5 46.1-49.3
30 39.0-41.8 41.1-44.0 44.8-47.9 49.0-52.4 52.3-55.9 58.1-62.0 62.6-66.9
35 50.6-54.1 54.1-57.8 60.3-64.4 65.2-69.6 74.1-79.1
40 67.9-72.5 77.7-82.9 85.8-91.5
45 81.5-87.0 90.5-96.5 108.1-115.3