Part Number 80-1479-3 10/10 3
Installation
Location of Ice Machine
The location selected for the ice machine must meet
the following criteria. If any of these criteria are not
met, select another location.
The location must be indoors.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 10ºC but must
not exceed 43.4ºC.
The location must not be near heat-generating
equipment or in direct sunlight.
The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
The location must allow enough clearance for water,
drain, and electrical connections in the rear of the
ice machine.
The location must not obstruct airflow through or
around the ice machine (condenser airflow is in and
out the front). Refer to the chart below for clearance
requirements.
*NOTE: The ice machine may be built into a cabinet.
There is no minimum clearance requirement for the
top or left and right sides of the ice machine. The listed
values are recommended for efficient operation and
servicing only.
Self-Contained
Air-Cooled
Self-Contained
Water-Cooled
Top/Sides 203 mm (8")* 127 mm (5")*
Back 127 mm (5")* 127 mm (5")*