–140–
EC65 SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle Harvest Cycle
Discharge Pressure Suction Pressure Discharge Pressure Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
10 12.06-9.65 4.13-1.80 6.21-8.27 4.83-5.87
20 16.20-12.41 4.83-1.93 7.58-10.69 5.52-8.62
25 17.58-14.48 4.83-2.07 7.92-11.72 6.89-9.31
32 20.68-17.24 5.17-2.21 8.27-13.79 7.93-10.34
43 26.20-22.06 5.52-2.48 8.96-14.82 8.96-12.07