–131–
EC50 SELF-CONTAINED AIR-COOLED — LARGE CUBE (Continued)
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle Harvest Cycle
Discharge Pressure Suction Pressure Discharge Pressure Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
10 9.31-4.48 2.76-.14 2.76-4.83 1.38-2.76
20 14.48-6.21 3.31-.14 4.14-7.58 1.72-4.48
25 14.48-7.58 3.45-.14 4.82-8.27 2.07-4.82
32 17.23-8.96 3.79-.14 6.21-9.65 2.76-5.87
43 24.13-12.07 4.27-.21 7.93-12.76 3.45-7.93