22 Part Number 80-1479-3 10/10
Step 13 Remove Water Curtain and Ice Chute.
Step 14 Take all components to sink and with 10 liters
Sanitizer/Water mixture sanitize all components with a
soft nylon brush or cloth. Do not rinse components.
Step 15 Use brush or cloth to sanitize the inside of ice
bin. Scrub inside of door, door track, bin, water sump,
water distribution assembly and evaporator moldings.
Do not rinse.
Step 16 Replace sump drain over flow tube, and
transfer remaining 2 liters of solution to the sump
trough. Replace all components.
Step 17 To start a sanitizing cycle, set the toggle
switch to the WASH
/FILL position.
Step 18 After 10 minutes, set the toggle switch to the
OFF position. Remove water curtain and ice chute
Remove over flow tube from water sump and allow all
water to drain from sump. Replace drain plug and fill
sump with 2 liters of water. Set toggle switch to WASH
/
FILL and circulate for 10 minutes.
Step 19 After 10 minutes, set toggle switch to off
position. Remove water curtain, ice chute, water sump
over flow tube. Drain water from sump and replace
tube.
Step 20 Replace all parts. Connect the incoming ice-
making water line
.
Step 21 Place toggle switch to the WASH/FILL for 90
seconds and then to ice position,ice machine will go
into ice making cycle.