EasyManuals Logo

Manitowoc Grove GMK 5200-1 User Manual

Manitowoc Grove GMK 5200-1
346 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
Maintenance overview
5.4 Measures required for winch monitoring
09.03.2018
Maintenance manual 3 302 746 en 5 - 27
GMK5200-1
The used proportion S
2
of theoretical service life after the second inspection
is therefore:
Remaining theoretical service life:
D2 = 3,040 h –1,920 h = 1,120 h.
The above values are entered in the table (see table example p. 5 - 28).
3
rd
inspection (3
rd
year)
The truck crane was used for assembly work and occasional unloading work
on docks: Load spectrum: L 2, i.e. Km
3
= 0.25.
The operating hours counter for the main hoist reads 940 h, i.e. during this
period: 940 h - 640 h = 300 h. T3 = 300 h.
The used proportion S
3
of theoretical service life after the third inspection is
therefore:
Remaining theoretical service life:
D3 = 1,120 h - 600 h = 520 h.
The values are entered in the table (see table example p. 5 - 28).
The remaining theoretical service life is to be documented in a separate
table for each winch.
This table is to be attached to the crane logbook. This table is to be found in
the maintenance manual's appendix for truck cranes that do not require a
crane logbook or similar documentation according to the regulations of the
respective country.
s
S
i
0.5
0.125
---------------
480 h× 1,920 h==
S
i
0.25
0.125
---------------
300 h× 600 h==

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5200-1 and is the answer not in the manual?

Manitowoc Grove GMK 5200-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5200-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals