Manitowoc Published 10-09-2020, Control # 259-06 4-1
MLC80A-1/MLC90A-1/MLC100A-1/MLC100-1 SERVICE/MAINTENANCE MANUAL BOOM
SECTION 4
BOOM
GENERAL MAINTENANCE
This section contains maintenance and adjustment
instructions for the limit devices used with the boom.
For maintenance and inspection of the following
components, see Section 5 of this manual:
• Wire rope
• Load block and weight ball
• Boom and jib
ROTATING BED LEVEL SENSOR
See Figure 4-1.
The rotating bed level sensor (1) is located inside the rotating
bed beside the swing motor. The sensor measures the angle
of the rotating bed and communicates the information to the
crane’s control system through the IOLC30 control module.
The angles are viewable in the Crane Status Bar of the Main
Display Working Screen.
To adjust the level sensor:
1. Move the crane onto a level surface.
2. Using a smart level, measure the crane’s roll and pitch at
the turntable bearing.
3. Securely fasten the level sensor (1) and the mounting
plate (2) to the bracket (3) with the screws, nuts, and
washers.
4. Loosen the nuts (8) and adjust nuts (7) at location A so
the roll and pitch shown in the main display match the
roll and pitch measured with the smart level.
5. Securely tighten the nuts (8).
FIGURE 4-1
Item Description
1 Level Sensor with Screws, Nuts, and Flat Washers
2 Mounting Plate
3 Bracket with Cap Screws and Lock Washers
4 Cap Screw (Qty 4)
5 Flat Washer (Qty 16)
6 Lock Washer (Qty 8)
7 Nut (Qty 8)
8 Nut (Qty 4)