TROUBLE DIAGNOSIS (continued)
CONDITION POSSIBLE CAUSE POSSIBLE SOLUTION
Boom chatters
during
extension/
retraction or
doesn’t
proportion
properly
Boom sections need lubrication.
Wear pads not shimmed correctly.
Worn wear pads.
Extension cables out of adjustment.
Extend or retract cables broken.
Grease boom.
Reshim as described in boom assembly section.
Replace pads.
Readjust cables and tension properly.
Disassemble and inspect and replace cables.
Boom will not
extend
Proportioning cables not attached.
Anti-two-block system shut down.
Defective anti-two-block system.
Reconnect, replace and/or adjust cables.
Lower hook, and extend load.
Check anti-two-block system; repair if defective.
Fo