M6 System | V4 | Installation
Hydrophone Cabling
You need to connect the hydrophone to a junction box.
The following cabling instructions are for hydrophones currently sold by Marport: NC-1-05,
NC-1-06, NC-1-07 and NC-1-08.
For information about obsolete hydrophones, please contact Marport support.
Passive Hydrophone
We recommend the following wiring for the installation of the wideband passive hydrophone
NC-1-05.
Beamwidth:
55°x 55° : only connect cell with black + green wires
55° x 35°: connect both cells
Note: To be able to receive water temperature from Marport hydrophones, on M3, M5 and
M6 systems connect to the NTC hydrophone input H1 or H2. On M4 system connect to the
hydrophone input 1 or 2 using an NMEA converter junction box (P/N: NC-2-TEMP).