47
User will get Error tone after disconnect signal is generated on
the FXS port.
How to program?
Use following command to program the signal to be generated as
Disconnect Signal on FXS port:
248-Disconnect Signal-#*
Where,
Disconnect
Si
gnal
Meaning
0 None
1 Polarit
y(Battery) Reversal
2
Open Loop Disconnect (Battery
Removal or Current Removal
)
By default, Disconnect signal on FXS port is 1.
Use following command to program the Open Loop Disconnect
timer on FXS port:
249-Open Loop Disconnect Timer-#*
Where,
Open Loop Disconnect Timer is from 001 to 999 ms.
By default, Open Loop Disconnection Timer is 500ms.