52 Chapter 4: Matrox Solios eV-CL hardware reference
The following tables summarize the auxiliary functionality that the PSGs support,
and the corresponding signals that the PSGs can receive/generate on Matrox Solios
eV-CLBL and Matrox Solios eV-CLFL. For example, P0_TTL_AUX_IO_0 can
be defined as a timer output (M_TIMER3), trigger input (trigger controller 0 on
acq path 0), field polarity input, user input, or user output (M_USER_BIT2).
Note that all auxiliary input signals are inquirable so they can be used as user input,
although not listed in the following table as a possible functionality.
LVDS cam. ct rl
TTL aux. I/O
*
OPTO aux. in
*
LVDS aux. in
*
LVDS aux. out
*
Camera Link
Connector
Camera Link
Connector
Camera Link
Connector
Camera Link
Connector
Camera Link
Connector
0 1 0 1 0 1 0 1 0 1
M_AUX_IOx or
x 898923670110114512131213
M_CC_IOy
y12341234
for M_DEVz
z000011110 0 1 10/10/10 00/10/10 00/10/10 0 1 1
Functionality
A
c
q
u
i
s
i
t
i
o
n
p
a
t
h
C
C
1
C
C
2
C
C
3
C
C
4
C
C
1
C
C
2
C
C
3
C
C
4
P
0
_
T
T
L
_
A
U
X
_
I
O
_
0
P
0
_
T
T
L
_
A
U
X
_
I
O
_
1
P
1
_
T
T
L
_
A
U
X
_
I
O
_
0
P
1
_
T
T
L
_
A
U
X
_
I
O
_
1
T
T
L
_
A
U
X
_
I
O
_
0
T
T
L
_
A
U
X
_
I
O
_
1
P
0
_
O
P
T
O
_
A
U
X
_
I
N
0
P
0
_
O
P
T
O
_
A
U
X
_
I
N
1
O
P
T
O
_
A
U
X
_
I
N
0
O
P
T
O
_
A
U
X
_
I
N
1
P
0
_
L
V
D
S
_
A
U
X
_
I
N
0
P
0
_
L
V
D
S
_
A
U
X
_
I
N
1
L
V
D
S
_
A
U
X
_
I
N
0
L
V
D
S
_
A
U
X
_
I
N
1
P
0
_
L
V
D
S
_
A
U
X
_
O
U
T
0
P
0
_
L
V
D
S
_
A
U
X
_
O
U
T
1
P
1
_
L
V
D
S
_
A
U
X
_
O
U
T
0
P
1
_
L
V
D
S
_
A
U
X
_
O
U
T
1
Timer
(M_TIMER
x
)
0 1/2 1/2 1/2 1/2 3 1/4 2 1 2
1 1/2 1/2 1/2 1/2 3 1/4 2 1 2
Trigger controller
affected by input signal
0 T1T1 T3T0T1T2T3T0T1T2T3
1 T0 T1 T1 T3 T0/
T2
T1/
T3
T0/
T2
T1/
T3
Field polarity input
0000
1000
Timer-clock input
0 0
1 0
Bit of quadrature input
**
0 01
1 01
*. On external auxiliary I/O connector 0 (DBHD-44).
. MIL constant, where
x, y,
and
z
correspond to the numbers in the row. M_DEVz is the required device number of the digitizer (
MdigAlloc()
) that you must use to
access this signal.
. On external auxiliary I/O connector 1 (DB-9).
**. Note that a rotary encoder (starting with Matrox Solios XCL Version 100) with quadrature output transmits a two-bit code. The table entries denote bit position.

Table of Contents

Related product manuals