86 Appendix B: Technical information
Pin Hardware signal name MIL constant
for auxiliary
signal
*
Digitizer
device number
for auxiliary
signal
Description
1 P0_TTL_AUX_IO_0 M_AUX_IO8 M_DEV0 TTL auxiliary signal (input/output) for acquisition path 0, which
supports: timer output (M_TIMER3 on M_DEV0), trigger input
(trigger controller 0 on acq path 0), user input, user output
(M_USER_BIT2), or field polarity input.
2 P0_TTL_AUX_IO_1 M_AUX_IO9 M_DEV0 TTL auxiliary signal (input/output) for acquisition path 0, which
supports: timer output (M_TIMER1/M_TIMER4 on M_DEV0),
trigger input (trigger controller 1 on acq path 0), user input, or
user output (M_USER_BIT3).
3 TTL_AUX_IO_0 M_AUX_IO2 M_DEV0,
M_DEV1
TTL auxiliary signal (input/output), shared between both
acquisition paths for trigger input (trigger controller 2 on acq path
0; 2 on acq path 1), user input or user output (M_USER_BIT4),
and dedicated to acquisition path 0 for timer output (M_TIMER2
on M_DEV0).
4+,5- P0_LVDS_AUX_IN0 M_AUX_IO10 M_DEV0 LVDS auxiliary signal (input) for acquisition path 0, which
supports: trigger input (trigger controller 0 on acq path 0), user
input, field polarity input, or quadrature input bit 0.
6+,8- P0_LVDS_AUX_IN1 M_AUX_IO11 M_DEV0 LVDS auxiliary signal (input) for acquisition path 0, which
supports: trigger input (trigger controller 1 on acq path 0), user
input, timer clock input, or quadrature input bit 1.
7 GND Ground.
10 GND Ground.
12+,11- P0_OPTO_AUX_IN1 M_AUX_IO7 M_DEV0 Opto-isolated auxiliary signal (input) for acquisition path 0, which
supports: trigger input (trigger controller 1 on acq path 0) or user
input.
13+,14- P0_LVDS_AUX_OUT0 M_AUX_IO12 M_DEV0 LVDS auxiliary signal (output) for acquisition path 0, which
supports: timer output (M_TIMER1 on M_DEV0) or user output
(M_USER_BIT0).
15+,9- P0_OPTO_AUX_IN0 M_AUX_IO6 M_DEV0 Opto-isolated auxiliary signal (input) for acquisition path 0, which
supports: trigger input (trigger controller 0 on acq path 0), user
input, or field polarity input.
- NC Not connected.
*.
These MIL constants represent the signals as of MIL 10. The signals that were previously represented by M_HARDWARE_PORTn became represented by
M_AUX_IOn (w here the value of n remained the same between the constants). For a complete list of changes between previous MIL versions and MIL 1 0,
see
MILSoliosCameraLinkIOConversionTable