77
Troubleshooting
Phenomenon Cases not involving a machine defect
Reference
page
No image is
displayed via
HDBaseT.
Check the LAN cable if it is CAT5e certied or higher.
Try to change the LAN cable.
If the LAN cable is connected with more than 3 extension
connector, the transmission of 100 meters may fail.
Check if the extension connector is compatible with
CAT5e.
All LAN cable and extension connector connected with
HDBaseT port must be CAT5e certied.
No image is
displayed via
SDI.
Check if it is connected with a cable of 5CFB or greater,
or Belden 1694A or greater.
Check if a cable with a length of 100m or less is used.
Try to change the cable.
Check if a supported signal format is input.
(continued on next page)
Phenomena that may be easy to be mistaken for machine defects (continued)