Product description
0000000141 - 002 - EN 16
3.2 Intended use
Within their technical limits, gas boosters are used to deliver and compress suit-
able types of gases.
If the gas booster bears an ATEX label and comes with a declaration of conformi-
ty, it is designated for use in corresponding potentially explosive areas.
3.3 Foreseeable misuse
The product may only be used in accordance with the indications in this manual.
The product cannot be used for:
– breathing air
– sealing containers
– producing / processing food with direct contact
– producing pharmaceutical products in direct contact
3.4 Misuse
Unauthorised modifications or technical changes to the product may lead to ac-
cidents with serious or fatal injuries.
Never carry out unauthorised modifications or technical changes to the product!
3.5 Ports
Comply with the connected load specifications for all interface connections. Re-
fer to the enclosed general drawing for the connection ports available on the gas
booster.
The following interfaces are standard on the gas boosters:
Drive air inlet “P
L
“
Input of drive fluid.
Gas inlet “A”
Input of operating fluid.
Gas outlet “B”
Output of operating fluid.
Exhaust port “E”
Output of expanding drive fluid.
Control air port “X”
Port for control air. The gas booster only operates if the control air connection is
pressurized. The pressure of the control air must always be larger or equal to the
drive pressure to ensure proper function. The same requirements regarding
compressed air quality apply to the control air as to the drive air.