Maintenance
0000000141 - 002 - EN 30
7 Maintenance
7.1 Maintenance intervals
To ensure safe and smooth operation, the gas boosters must be checked regular-
ly and serviced, cleaned or repaired as necessary. The individual maintenance ac-
tivities are described in the following section.
Maximator recommends the intervals listed below. These intervals are calculat-
ed based on 1,300,000 strokes / year.
The required maintenance intervals depend on the system and application. The
intervals must be adjusted based on the given conditions of use.
Tab. 7-1 Maintenance intervals
Activity
before and after each
use
daily
weekly
monthly
quarterly
semi-annually
annually
as needed
System inspection x
Leak-testing the connec-
tions
x
Check screw fittings and
connecting lines for
damage
x
Clean gas booster x
Check fastening ele-
ments and connecting
elements
x
Test for leakage x
Repair gas booster x