Installation
23 0000000141 - 002 - EN
4.4 Storage
Note the following with regard to package storage:
– Do not store the packages out of doors.
– Keep the packages dry and dust-free.
– Do not expose the packages to corrosive media.
– Keep the packages protected from sunlight.
– Prevent mechanical vibrations.
– Maintain a storage temperature of -20°C to +60°C.
– The relative humidity should not exceed 60%.
Storage instructions in addition to the specifications mentioned here may be at-
tached to the packages.
Maintenance during storage
Even under the aforementioned storage conditions, the gas booster cannot be
stored indefinitely.
– If in storage for longer than 3 months: Inspect the packaging and the gas
booster for damage on a regular basis.
– Replace all the seals at least every 6 years.
– The gas booster must be briefly operated every 6 weeks. In doing so, con-
nect drive air of at least 3 bar. A resistance of 2 bar at the outlet is sufficient
to briefly activate the sealing element.
5 Installation
5.1 Prerequisites for installation
Comply with the manual and the general drawing of the product.
In addition, the following conditions apply:
– The product must be free of damage.
– The product must be securely mounted.
– Do not expose the product to any vibrations.
– The product must be easily accessible from all sides.
– Do not expose the product to any external heat or radiation sources.
– Install the product in a clean environment.