Maintenance
0000000141 - 002 - EN 32
7.2.1 System inspection
The following section explains how to check the gas booster for proper function:
7.2.2 Leak-testing the connections
The following section explains how to check the connections for leaks:
Description
Qualifications Operating the system
Type of mainte-
nance
Check
Interval weekly
1. Shut off the gas outlet and adjust p
B
to a value that is standard for the sys-
tem.
The gas booster stops automatically when the final pressure is reached.
(dwell time of 30s)
2. Relieve p
L
.
P
B
does not drop by more than 10%. (dwell time of 30s)
3. Set P
L
to approx. 50% of the value from the first step and slowly relieve P
B
.
The gas booster starts up automatically.
2. If the inspection does not reveal any abnormalities, it is safe to continue us-
ing the gas booster.
In case of abnormalities, consult with the maintenance staff.
Description
Qualifications Operating the system
Type of mainte-
nance
Check
Interval weekly
Prerequisites The gas booster is easy to access.
All connections are pressurised.
Tools Torch
Cleaning cloth
Leak detection spray
1. Check connections for leaks.
Use leak detection spray.
2. If the inspection does not reveal any abnormalities, it is safe to continue us-
ing the gas booster.
In case of abnormalities, consult with the maintenance staff.