Mounting Installation Plate
Ensure that the wall is strong enough to withstand the 
weight of the unit. Otherwise, it is necessary to reinforce 
the wall with plates, beams or pillars.
Use the level gauge for horizontal mounting, and fi x it 
with 5 suitable screws.
In case the rear piping draws out, drill a hole 65mm in
diameter with a cone drill, slightly lower on the outside 
wall (see fi gure).
166
184
181.7
55.554.5
153.8
263
51.9
800
9
.5
4
2
.2
4
882
2.24
9.54
Recommended Mounting Plate Retention Spots And 
Dimensions
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of the 
installation plate (Engage the two hooks at the rear top 
of the indoor unit with the upper edge of the installation 
plate). Ensure that the hooks are properly seated on the
installation plate by moving it to the left and right.
How To Attach The Indoor Unit
Hook the claws of the bottom frame to the mounting 
plate.
How To Remove The Indoor Unit
Push up the marked area (at the lower part of the front 
grille) to release the claws.
Water Drainage Piping
The indoor drain pipe must be in a downward gradient for 
smooth drainage. Avoid situations that are likely to cause 
water to leak.
• Do not install the unit at altitude over 2000m for both 
indoor & outdoor.
CAUTION
Mounting plate 
fi xing screw
Mounting plate
Mounting plate
Clip
Mark (Rear side)
Bottom frame
Front grille
When stripping the ends 
of interconnecting wires in 
advance, bind right ends 
of wires with insulating 
tape.
Mounting plate
Hand indoor unit’s hook here.
Wire guide
Interconnecting 
wires
Water Drainage
Correct Wrong Wrong Wrong
Water 
Leaking
Water 
Leaking
Water 
Leaking
Water 
Retention
End 
dipped 
into 
water
Drain
Recommended mounting plate
retention spots (5 spots in all)
Use tape measure as shown.
Position the end of a tape 
measure at 
X
Through
the wall
hole
Ø 65mm
Drain
hose
position
Gas pipe endLiquid pipe end
All dimensions are in mm
Hole with cone drill
Wall embedded pipe
(Field supply)
Caulking
OutsideInside
Ø 65
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
MacQuay IM-WMJ-1110(0).indd   7MacQuay IM-WMJ-1110(0).indd   7 1/12/2011   6:26:00 PM1/12/2011   6:26:00 PM