101
41: Abnormal AI input fault (Er.AIF
abnormal analog input)
42: Inverter module temperature
sampling disconnection protection
(Er.THI)
43: Rectifier module temperature
sampling disconnection protection
(Er.THr)
44: Short circuit of ±10V analog output
power (Er.10v)
45: Abnormal internal over-current
reference (Er.rEF)
46~50: Reserved
Note:
1. Er.drv fault can not be reset until 10s
later;
2. For continuous over-current less
than 3 times (including 3 times), it can
not be reset until 6s later; if it is more
than 3 times, it can not be reset until
200s later;
3. The keyboard displays AL.xxx in
case of any fault (e.g. in case of the
contactor fault, keyboard displays
Er.xxx if there is protection action, and
displays AL.xxx if continuing running
with alarm)
P97.16
The second
fault type
The second
fault type
The same as P97.15 1 0 × √ *
P97.17
The third
fault type
The third
fault type
The same as P97.15 1 0 × √ *
P97.18
DC bus
voltage at
the 3rd fault
DC bus
voltage at
the 3rd fault
0~999V 1V 0V × √ *
P97.19
Actual
current at
the 3rd fault
Actual
current at
the 3rd fault
0.0~999.9A 0.1A 0.0A × √ *
P97.20
Running
frequency
at the 3rd
fault
Running
frequency at
the 3rd fault
0.00Hz~3000.00Hz 0.01Hz 0.00Hz × √ *
P97.21
Drive
running
status at the
3rd fault
Drive
running
status at the
3rd fault
0~FFFFH
The same as P01.17
1 0000 × √ *
P97.22
Inverter
module
temperature
at the 3rd
fault
Inverter
module
temperature
at the 3rd
fault
0.0~150.0℃ 0.1℃
0.0 × √ *