11. Scaling of drive parameters
1. Scaling of the frequency: 1:100
To make the drive run at 50 Hz, the main setting shall be 0x1388 (5000).
2. Scaling of time: 1:10
To make the acceleration time of the drive to be 30 s, the function code shall be set as 0x012C (300).
3. Scaling of current: 1:10
If the feedback current of the drive is 0x012C (300), the present current shall be 30 A.
4. The output power is its absolute value.
5. For other parameters, please refer to the function parameter descriptions.