P08.04 sets the volume of the startup DC braking current, which is indicated in a percentage of the rated
current of the drive.
G: 0.0~100.0%
;P: 0.0~50.0%
P08.05 sets the action time for the startup DC braking.
Different stop modes can be adopted for different applications.
0: Decelerate to stop
Decelerate to stop according to the set deceleration time.
1: Coast to stop
The drive locks the output and the motor coast to stop.
2: Decelerate to stop + DC braking
Decelerate to stop according to the set deceleration time, and when the frequency is lower than the DC
braking initial frequency P08.12, inject the DC braking current P08.14 after the stop DC braking waiting
time P08.13. The stop DC braking is determined by P08.15.
Detecting the frequency upon the stop action is finished.
The retention time for detecting the frequency upon the stop action is finished.
Begin to inject the initial frequency of the stop DC braking current during the stop process set by P08.12.
P08.13 waiting time for the stop braking: The time interval from the moment when the running frequency
reaches the initial frequency for braking (P08.12) till the DC braking is injected during decelerating to
stop.
P08.14 sets the volume of the stop DC braking current, which is indicated in a percentage of the rated
current of the drive.
G: 0.0~100.0%
;P: 0.0~50.0%
P08.15 sets the action time for the stop DC braking.
Stop frequency detection retention time
0.00~10.00s
0.00s
P08.08
Initial frequency for stop DC braking
0.00~60.00Hz
0.00Hz
P08.12
Stop frequency detection
0.00~150.00Hz
0.50Hz
P08.07
Stop DC braking time
0.00~30.00s
0.00s
P08.15
Sto
DC brakin
current 0.0~100.0% / 0.0~50.0%
0.0%
P08.14
Waiting time for stop DC braking
0.00~10.00s
0.00s
P08.13
Reserved 0
P08.09~P08.11
Stop mode
0~2
0
P08.06