Function code Function description
P00.03 Parameter protection setting
P02.01 Motor selection
P09.00~P09.05 Input terminals X1~ X6 function selection
P02.04 Main reference frequency selection
P02.06 Main reference & auxiliary reference frequency control
P13.16 PLC running mode
P03.00 Rated power of motor 1
P03.12 Rated power of motor 2
P03.04 Rated rotating speed of motor 1
P03.16 Rated rotating speed of motor 2
P98.06 Drive series selection (manufacturer parameters)
3. Some control parameters cannot be stored into the nonvolatile memory cell. So for these parameters, the
command codes 0x41 and 0x06 have the same operation effect, as well as 0x43 and 0x10, that is, write
operation. Once power on again after power off, the parameters will not be saved. Please refer to the control
parameter table for details.
4. Some internal parameters of MV200 drive are reserved, which cannot be modified through the
communication setting. These parameters are as show in the following table:
Function code Function description
P00.00 Menu mode selection
P00.06 Parameter copy
P03.24 Motor parameter auto-tuning
5. The operation of the host device on the user password
1) Managing the read/write and function codes of function code parameters of the user password protection
(except for “read the address of the data displayed” and “display the data switching”).
2) If the user password is set (P00.01), the host device can access to the function code parameters only after
“decryption” (write the correct user password to P00.01), but the access to the control parameters and status
parameters is not restricted by the user password.
3) The host device cannot set, change or cancel the user password and only the operation panel is able to
conduct these operations. The writing operation of P00.01 will be valid only in two situations: decrypt with the
password, and write 0 without the password. In other situations, the invalid operation information will be
returned.
4) The operation of the host device and that of the operation panel on the user password are independent,
even if the operation panel has decrypted already, the host device still need to decrypt to access to the
function code parameters, and vice versa.
5) When the host device gets the authority to access to parameters, it will read the user password and return
to “0000” rather than the actual user password.