28 
10V~0
20mA~0
20mA~0
10V~10V-
4V2~0
 
Fig. 3-4  Basic wiring diagram 2 
Note: 
1. For AI1 and AI2, the input voltage signal or the current signal can be selected via the jumper. The function 
code P10.00 shall be changed after the hardware jumper finished selection to ensure the correct input signal.   
2. For AO1 , the output voltage signal or the current signal can be selected via the jumper, and the output 
range is selected and determined by the function code P10.22.   
3. If external braking components need to be configured, the braking unit and braking resistor shall be used. 
Please pay attention to the positive and negative polarity when connecting the braking unit.