Safety
2. Safety Instructions
2.1. General
The Proveno combi-kettle has been designed and manufactured in compliance with the Directive regar-
ding Safety of Machinery, the Low Voltage Directive, the Directive regarding Electromagnetic Compatibi-
lity and the Directive regarding Pressure Equipment currently in force.
The Proveno combi-kettle is a pressurized vessel with a maximum operating pressure of 1 bar (or 0,5
bar for certain markets). Overpressure is prevented by means of both mechanical (safety valve, pressure
switch) and electronic control.
The Proveno combi-kettle is provided with water level control, which prevents heating if there is not
enough water in the steam generator.
Heating, mixing, water fi lling or cooling do not function when the kettle is tilted. All functions of the kettle
are interrupted when the emergency/stop switch is pressed. The switch is released by turning it to the
right.
The manufacturer does not take responsibility for consequences caused by incorrect use or use against
the operation instructions.