EasyManua.ls Logo

Metos PROVENO E - Power Failure During Start;Operation

Metos PROVENO E
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
|
39
PROVENO E
Rev. 1.2 (24.08.2016)
Operation instructions
Power failure during both the starting time and operation time
In case of power failure during both the starting time and operation time, the kettle’s timer display shows,
when the power supply is restored, the total time the timing was delayed:
during operation time, letter E + total delayed time in hours and minutes and the remaining operation
time alternate on the display, e.g. E1.22 / r0.27, and the green indicator light on the operation time
button is blinking
after operation time, the display shows letter E + total delayed time in hours and minutes, e.g. E1.22,
and the green indicator light on the operation time button is blinking
in case of several power failures, their durations are summed up
After a power failure the kettle must be switched off and on again with the ON/OFF button in order to
reset the power failure counters.
4.2.16. Programming lockup reset
In the eventual case that wrong EasyRun 1.1 or 99.9 programming locks up the kettle display and turning
the kettle off and on doesn’t release the lockup there is a reset startup sequence that resets incorrect
programming parameters and releases the lockup situation.
The reset is done in the following way,
turn the kettle off
push the central dial and keep it pushed
turn the kettle on
the temperature display shows the fi rmware revision of the kettle and all the button leds are on
while the central dial is pushed push the
–button and keep it pushed until the display shows
‘Er1’ and the button led fl ashes
keep both the central dial and the button pushed until the ‘Er1’ message disappears and the button
led goes off
turn the kettle off and on again
now the lockup is reset