PROVENO E
Rev. 1.2 (24.08.2016)
Adjustment instructions
6.2. Customer specifi c parameters, settings and factory presets
The following table contains the parameter values starting from program revision 2r01. The program revi-
sion is visible on the temperature display a short moment after switching the kettle on.
Pr code Function Display Value Factory pre-
set
Pr10 Default cooking temperature Temperature
Timing
hPt
0 - 120
80
Pr11 Used temperature unit Temperature hEC
hEF
Celsius
Fahrenheit
hEC
Pr12 Default Hold temperature automatically set
after the cooking process
Temperature
Timing
hold
51 - 100 70
Pr13 Central dial selection delay (sec.) after which
the selected value is locked
Temperature td_2 - td_7 td_5
Pr14 Low-temperature area (51-69°C heating
temperature difference
Temperature hd 0 - hd30 Hd10
Pr15 Mid-temperature area (70-87°C) heating
temperature difference
Temperature nd 0 - nd30 87°C temperature
xed 100°C
nd30
Pr16 Cooking temperature area 88-100°C)
heating temperature difference
Temperature Hd 0 - Hd13 Hd13
Pr20 Selection and deselection of the short pull
back of the tilting done after releasing the
tilting
Temperature Fbon
FboF
Pull back ON
Pull back OFF
Fbon
Pr21 Selection and deselection of the buzzer sig-
nal used when pausing and ending the mixer
Temperature
Mixer
AL
on
oFF
Buzzer ON
Buzzer OFF
on
Pr22 Forced slow mixing when tilting Temperature
Mixer
FC15
on/off off
Pr23 PIN code (only EaryRun 99.9 programming) Temperature
Water fi ll
Info
PIn
Set/Old
_ _ _ _ _ _ _ _
Pr24 PCo cooling mixer speed Temperature
Mixer
PCoS
15-50
25
Pr30 Water bypass time (min.) of the automatic
water fi lling system. Used to empty long
water supply lines of possibly musty water.
Temperature
Water fi ll
Fti
0 - 10 0 = no bypass
ow done
1
Pr31 Water bypass interval (hours) of the automa-
tic water fi lling system. When the interval
has elapsed a new bypass fl ow is done.
Temperature
Water fi ll
Fdi
0 - 24 0 = bypass fl ow
always done
12
Pr32 Automatic water fi lling unit selection Water fi ll Lit/GAL Att!
Pr01
Lit
Pr33 Pure function behaviour in EasyRun pro-
gramming
Temperature
Water fi ll
FEr
OFF
Pr31
On
OFF=Pure never done
Pr31=Pure done ac-
cording to Pr31 setting
On=Pure always done
OFF
Pr40 Default cooling fi nal Temperature
Info
CFt
0 - 100 30
Pr41 C5 cooling temperature setpoint when tap
water cooling is changed to Ice Bank
Temperature
Info
C2C3
0-100
0=C2
100=C3
75