64
|
PROVENO E
Rev. 1.2 (24.08.2016)
Adjustment instructions
Pr code Function Display Value Factory pre-
set
Pr42 C5 cooling tap water emptying delay before
Ice Bank emptying delay
Temperature
Info
C5td
0-15
0 = not in use
0
Pr43 Preset time (min.), after which the cooling is
aborted if the temperature doesn’t decrease
any more
Temperature
Info
Cdt2
0 - 4.00
0 = cooling abortion
switched off 0.15
Pr44 Mixer program 1 - soft mixing
Activated when set cooling temperature
reached
Temperature
Mixer
Soft
on/off
off = pause 2 min
on = pause 10 min
Att!
Pr01
OFF
Pr50 No longer used
Pr51 Appliance identifi cation code for the
HACCP data collection
Temperature
Mixer
HAC2
0 - 99
0 = HACCP
switched off 0
Pr52 Setting of HACCP data collection interval
(min.)
Temperature
Mixer
HAC3
1, 5 or 10 1