Troubleshooting
7. Troubleshooting
MALFUNCTION POSSIBLE CAUSE WHAT TO DO
The kettle cannot be
switched on
The mains switch is in the OFF position Turn the mains switch tted on the rear part of the
control pillar right side to the ON position
The emergency/stop button is pushed Release the emergency-stop switch by turning it
clockwise
The fuses in the main fuse box areblown/
triggered
Change/excite the fuses
The delivery of electric energy is interrupted Check if the delivery of electric energy is interrupted
elsewhere and wait for it to return
The kettle does not heat The timer function is activated if the kettle is
equipped with a timer
Switch off the timer function according to instructions
The EasyRun function is activated if the kettle
is equipped with the option
Switch off the EasyRun function according to instruc-
tions
The emergency/stop button is pushed Release the emergency-stop switch by turning it
clockwise
The ON/OFF switch is not in the ON position Push the switch to the ON position
On a kettle fi tted with automatic cooling: The
draining of the cooling water is still unfi nished
Wait until time on the display next to the cooling but-
ton runs out
The fuses in the main fuse box are blown/
triggered
Change/excite the fuses
The kettle is not returned to an upright position
after tilting, the temperature display shows a
'PoS' signal
Press the tilting reverse button until the kettle is to-
tally horizontal and the temperature display shows an
'On' signal
Electric kettle: Not enough water in the steam-
generator, the two red error lights on the cont-
rol panel are illuminated
Check that the shut-off valve of the water supply line
is in the OPEN position
Steam kettle: The shut-off valve of the steam
input is closed
Open the valve
Other technical fault Contact qualifi ed technical personnel
Heating of the kettle is
slow
Electric kettle: Too much water in the steam-
generator
Check the water level of the steam generator accor-
ding to the instructions by opening the emptying valve.
Steam kettle: Condensate water gathered in
thesteam jacket has not been emptied
Remove the condensate by opening the emptying
valve which is in the steam jacket
The steam jacket of a kettle equipped with a
manual cooling system (C1) is full of cooling
water which has not been emptied
Remove the chilling water by opening the emptying
valve (electric) or the emptying valve for condensate
(steam)
There is air in the steam jacket which does
ow out because the automatic vacuum valve
does not function
If the air does not exit through the automatic vacuum
valve, contact qualifi ed technical personnel
One of the fuses in the main fuse box is
blown/triggered
Change/excite the fuse
The forced 1/2-power control of the building is on Normal operation
Other technical fault Contact qualifi ed technical personnel