23
VIKING 4G E, S
Rev. 1.0 (29.1.2020)
Operation instructions
Interrupting the automatic water fi lling.
• The function is interrupted by pushing the automatic fl ow on/off button.
• The achieved value stays on the display and the decimal point is blinking.
• The set value is saved in the memory.
• In the interrupted mode, the setting can be changed using the
and buttons.
• The water dispenser reverts to the basic mode by pushing .
• If the function is interrupted by pushing the emergency-stop button, the appliance reverts to the basic
mode and the settings must be done again.’
Continuing the automatic water fi lling after interruption
• The fi lling will continue from the achieved value up to the set value by pushing the button.
• After this the decimal point will illuminate continuously.
Error in automatic water fi lling
• If there is an error in fl ow measurement or if water does not fl ow, the value on the display blinks.
• The water dispenser reverts to the basic mode by pushing either or .
Settings
Maximum fi lling amount
• The maximum fi lling amount has been set in the factory according to the kettle size.
• The setting is changed by fi rst pushing the button and immediately after that the button for
5 seconds, after which the display value starts to blink. The new setting value according to the kettle
size is set using the and buttons. The maximum set value is 400 liters.
• The set value is saved if the setting is not changed in 5 seconds.
Calibration of fl ow measurement
• Basic calibration has always been done in the factory, so normally it need not be done again.
• If, however, calibration is needed, fi rst push the -button and immediately after that the but-
ton for 5 seconds after which the value 855 starts to blink on the display.
• To decrease the fl ow, push the button, so the value decreases. To increase the fl ow, push the
button, so the value increases. The amount of fl ow must be checked by pouring 5 liters of water
into a measuring vessel.
• The set value is saved if the value is not changed within 5 seconds.