Operation instructions
5.2.5. Water fi lling
Basic mode
• Whan the kettle is switched on 0 appears in the last digit’s position.
• The decimal point is illuminating.
• The values for the set amount of water and acheived amount of water are 0.
• If the function of the appliance is interrupted by switching off the control voltage, the switching on
again will always set it to this basic mode.
Manual water fi lling
• Filling starts when the button is pushed and held down for the duration of fi lling.
• The display is updated with an accuracy of one liter as long as the button is held down.
• The achieved value in liters is shown on the display for 10 seconds after stopping the fi lling. Then 0
appears on the display.
• If you want to continue fi lling within the mentioned time, the value on the display will continue in-
creasing.
Automatic fi lling of water
• Set the desired amount (liters) with the and buttons.
• The value is shown on the display for 10 seconds after which the set value will be 0.
• Start the water fi lling by pressing the button while the set value is illuminating on the display.
• After starting the fi lling function, the display will cumulatively show the amount of water fi lled (in
liters) and the fl ow stops automatically when the set value has been achieved. The set value is reset
to zero by pushing the button.
1. 3-digit display
2. Automatic fl ow on/off
3. Manual fl ow + reset
4. Setting is increasing
5. Setting is decreasing
Manual water fi lling
• Start the fi lling by turning the switch to fi ll position. The fi lling continues as long as the switch
is in this position.
1. Manual water fi lling switch
Automatic water fi lling (option)
A desired amount of cold water can be dispensed to the kettle by the automatic water dispenser in the
following way:
• water fi lling is manually kept on until the desired amount of liters appears on the display of the control unit
or
• automatic water running stops when the amount of liters set beforehand in the control unit are achieved.
1