5.4. Troubleshooting
The kettle does not heat up
• The kettle is not in upright (cooking) position. Return the kettle to upright position.
• Steam supply problems on a steam heated kettle. Check the steam supply and pressure.
The mixer does not start
• The kettle is not in upright (cooking) position. Return the kettle to upright position.
• The lid is open. Close the lid.
• The safety grid is not in correct position. Check the safety lid.
The cooling does not work
• The kettle is not in upright (cooking) position. Return the kettle to upright position.
• Jacket fi lling problems. Check the water supply (tap water cooling).
Resetting the unit
• Turn the main power switch to position 0 and wait for about 1 minute. Turn the main power switch to
1 position.