MI 3125 InstaltestCOMBO Table of contents
4
6 Maintenance..........................................................................................................47
6.1 Fuse replacement............................................................................................47
6.2 Cleaning ..........................................................................................................47
6.3 Periodic calibration ..........................................................................................47
6.4 Upgrading the instrument ................................................................................47
6.5 Service ............................................................................................................48
7 Technical specifications ......................................................................................49
7.1 Insulation resistance........................................................................................49
7.2 Continuity ........................................................................................................49
7.2.1 Resistance R LOW
Ω
........................................................................................... 49
7.3 RCD testing .....................................................................................................50
7.3.1 General data ....................................................................................................... 50
7.3.2 Contact voltage RCD-Uc..................................................................................... 50
7.3.3 Trip-out time ........................................................................................................ 51
7.3.4 Trip-out current.................................................................................................... 51
7.4 Fault loop impedance and prospective fault current ........................................51
7.4.1 No disconnecting device or FUSE selected ........................................................ 51
7.4.2 RCD selected ...................................................................................................... 52
7.5 Line impedance and prospective short-circuit current .....................................52
7.6 Socket test (RLN, RLPE, RNPE, RPE)............................................................53
7.7 Voltage, frequency, and phase rotation...........................................................53
7.7.1 Phase rotation ..................................................................................................... 53
7.7.2 Voltage ................................................................................................................ 53
7.7.3 Frequency ........................................................................................................... 53
7.7.4 Online terminal voltage monitor .......................................................................... 54
7.8 General data....................................................................................................54
A Appendix A - Fuse table.......................................................................................55
A.1 Fuse table - IPSC ............................................................................................55
B Appendix B - Accessories for specific measurements .....................................58

Table of Contents

Other manuals for METREL MI 3125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the METREL MI 3125 and is the answer not in the manual?

METREL MI 3125 Specifications

General IconGeneral
TypeMultifunction Installation Tester
Insulation ResistanceYes
Continuity TestYes
Loop ImpedanceYes
RCD TestingYes
Voltage MeasurementYes
Frequency MeasurementYes
DisplayLCD
Power Supply6 x 1.5 V AA batteries
Loop Resistance Resolution0.01 Ω
Frequency45 - 65 Hz
Line Voltage Resolution1 V
Insulation Resistance Test Voltage50 V, 100 V, 250 V, 500 V, 1000 V
Insulation Resistance Resolution0.01 MΩ
Continuity Resistance Resolution0.01 Ω
Test Current200 mA
DC VoltageUp to 600 V
Loop Resistance0.0 Ω - 1999 Ω
Line VoltageUp to 550 V
Line Voltage Accuracy±2% ±2 digits
Rated Residual Current10 mA, 30 mA, 100 mA, 300 mA, 500 mA
Insulation Resistance Range0.01 MΩ to 1 TΩ
Continuity Resistance0.0 Ω - 1999 Ω
Dimensions220 x 103 x 55 mm
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to +60°C
Safety StandardsEN 61557
Loop Resistance Accuracy±(5% + 3 digits)

Related product manuals