Test Voltage | 50 V, 100 V, 250 V, 500 V, 1000 V |
---|---|
Harmonics | Yes |
Power | Yes |
Data Logging | Yes |
Bluetooth | Yes |
Protection | Double insulation |
Type | Multifunction |
Measurement Category | CAT IV 300V, CAT III 600V |
Frequency | 15Hz to 400Hz |
Continuity | 0 - 2000 Ω |
Loop Impedance | 0 - 2000 Ω |
Line Impedance | 0 - 2000 Ω |
Earth Resistance | 0 - 2000 Ω |
Resistance Measurement | 0 - 2000 Ω |
Frequency Measurement | 15Hz to 400Hz |
Illumination | Yes |
Power Supply | Rechargeable battery |
Storage Temperature | -20 °C to 60°C |
General warnings, safety precautions, and critical notes for instrument usage.
Details instrument description, set contents, and carrying methods.
Explains keypad controls, touch gestures, virtual keyboard, and main menus.
Covers general settings, user accounts, profiles, workspace management, and initial settings.
Explains the tree structure, measurement statuses, structure objects, and navigation.
Describes measurement statuses (Pass/Fail) and the components of Structure Objects.
Explains how to select an active workspace within the Memory Organizer.
Guides on adding structural elements (Nodes) for data organization.
Details operations on measurements and structure objects like cloning, copying, deleting, and searching.
Explains how to clone structure objects and measurements.
Describes how to use the search function to find objects and parameters.
Explains the four modes for selecting single tests: Area Group, Groups, Cross selector, Last used.
Describes the layout and information displayed on single test measurement screens.
Guides on how to set test parameters and limits for single tests.
Details the options available on the single test start screen before measurement.
Explains the operations available while a single test is running.
Describes how to view, save, or retest results after a single measurement.
Explains how to edit graphs for Harmonics measurement results.
Details visual and functional inspections, including start, during, and result screens.
Explains how to access and use help screens for instrument connections.
Covers Voltage, Frequency, Phase Sequence, Insulation Resistance, DAR/PI, and Varistor tests.
Details R low, Continuity, Earth Resistance, and Specific Earth Resistance measurements.
Covers RCD testing (Uc, t, I, Auto), Loop Impedance, and Zs rcd measurements.
Details Z line impedance, Voltage Drop, and related auto tests like AUTO TT, TN, IT, Z auto.
Covers ISFL, IMD, PE Conductor Resistance, Illumination, Power, and Harmonics measurements.
Explains how to select, search, and organize pre-programmed Auto Sequences®.
Details step-by-step execution, result screens, and memory management for Auto Sequences®.
Covers USB, RS232, and Bluetooth communication for PC and Android devices.
Details communication with supported Bluetooth and serial scanners.
Details fuse replacement procedures and instrument cleaning instructions.
Emphasizes periodic calibration importance and provides service contact information.
Lists specifications for Insulation Resistance and Diagnostic tests (DAR/PI).
Details specifications for Earth, Continuity, and RCD testing functions.
Covers specifications for Z loop, Zs rcd, Z line, and Voltage Drop measurements.
Lists specifications for PE resistance, Earth resistance, Power, Harmonics, and Current measurements.
Provides general technical data including power supply, operating conditions, and communication ports.
Notes modifications for the Austria profile, including special delayed G type RCD support.
Covers safety warnings, measuring categories, and battery information for commanders.
Describes commander components and explains their operational status via LEDs.