Technical Specifications
50 50,000-count Benchtop Multimeter
Technical Specifications
Measuring
resistance
( )
@ Note
On this position, users can measure a resistance value.
(∗) with default-activated filter
Automatic or manual range selection.
Open circuit maximum voltage: 9 V.
A shielded cable is recommended for measurements exceeding 5 M.
Continuity mode
( )
On this position, users can measure a resistance value until 500 , with
continuous audible indication at 4 kHz.
Continiuty mode detection threshold 10 to 15 (reply time 1ms).
Open circuit maximum voltage: 9 V.
Diode test ( )
Indicating interface voltage in current direction from 0 to 4.5 V for only
one range
Precision: 0.2 % ± 3 D
Indicating overshoot in reverse direction
Measurement current: about 1 mA - V 2 V
Open circuit maximum voltage: 9 V
Rate Precision
Measurement
currrent
Resolution Protection
0 to 500
0.1% + 5D 1 mA
100 m
5 k
0.1% + 3D 100 µA
1
50 k
0.1% + 3D 10 µA
10
500 k
0.1% + 3D 1 µA
100
5 M (∗)
0.5% + 3D 100 nA
1 k
50 M (∗)
1% + 5D 50 nA
10 k
600 Vrms
Rate Precision
Measurement
current
Resolution Protection
Beeper 0.1% + 5D about 1 mA 100 m 600 Vrms
(cont.)