EasyManua.ls Logo

metso automation kajaaniMCAi - Mcai -FT

Default Icon
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
kajaaniMCA
i
– Installation, Operating & Service - 3.2 - W4610201 V2.5 EN
L
L
M in 600 m m (24")
3.C. MCA
i
-FT
When installed, the flow-through sensor forms part of
the process pipeline (Fig. 3.2). The sensor must be
installed so that the coupling of the Pt-100 temperature
sensor (inserted at an angle into the pipe) faces down-
stream. A sticker label on the sensor indicates the
direction of flow. Sensor models FT 150 and FT 200
contain no flanges; the sensor is fastened between the
flanges of the process pipe with clamp bolts. Models FT
100, FT 250 and FT 300 have fixed flanges. The
dimensions of the flanges and collars are given in
Appendix 5 of this manual.
3.2. Installation dimensions of MCAi-FT sensor (seen from above).
Model L/mm L/inch
150/6” 175 6 57/64
200/8” 225 8 55/64
Model L/mm L/inch
100/4” 300 11 13/16
250/10” 275 10 13/16
300/12” 350 13 25/32

Table of Contents