Installation, operating & service manual
W4610201 V2.5 EN
- for software version 2.5–>

Table of Contents

Questions and Answers

  • R
    robert98Aug 12, 2025
    What to do if there is a current signal fault in metso automation kajaaniMCAi?
    • H
      hallrobertAug 12, 2025
      If the MCAi reading and the current signal value do not match, ensure that the current signal cables are correctly connected before replacing the electronics of your Metso Automation Measuring Instruments.
  • G
    gregory43Aug 16, 2025
    How to fix a leak in the microwave antenna of Metso Automation Measuring Instruments?
    • C
      Chelsea PatelAug 16, 2025
      If you observe a slow drift of the measurement signal in one direction for your Metso Automation Measuring Instruments, it indicates a leak. Replace the antenna along with its cable to resolve this issue.
  • B
    Bradley ThomasAug 19, 2025
    What to do if there is antenna contamination in metso automation kajaaniMCAi?
    • M
      Madeline ColemanAug 20, 2025
      If the antenna of your Metso Automation Measuring Instruments gets cleaned periodically, especially when the wood species changes, the upwards drift caused by contamination may disappear.
  • B
    Bradley PowellAug 23, 2025
    How to resolve issues related to chemicals content in metso automation kajaaniMCAi Measuring Instruments?
    • P
      Peter VaughanAug 23, 2025
      A substantial increase in the chemicals content may attenuate the signal level below the low limit set for the self-diagnostics. The signal level can be increased by performing a new start-up (section 6.A) at the new, higher signal level. Large variations in the chemicals content may also cause error in the measurement, so you can use chemicals compensation to eliminate the error; see instructions in section 9.B or 12.C.1 (HART communicator).
  • A
    Anthony AdamsAug 27, 2025
    What to do if material is attached to the fork-type sensor of metso automation kajaaniMCAi Measuring Instruments?
    • M
      Mr. Steven BrownAug 27, 2025
      If you find string or other material attached to the fork-type sensor of your Metso Automation Measuring Instruments, install a deflector plate to divert these materials past the sensor. This kind of problem appears either as a drift in the measurement or as a rapid level change.
  • E
    Eric HerreraAug 31, 2025
    Why is there a temperature measurement error in metso automation kajaaniMCAi?
    • M
      Megan WestAug 31, 2025
      If the Pt-100 sensor connector is disconnected, defective Pt-100 sensor cable, defective Pt-100 sensor, or fault in Electronics Unit can cause temperature measurement error. First make sure that the Pt-100 sensor connector is securely connected to the Field Connection Board of your Metso Automation Measuring Instruments.
  • P
    Pamela BakerSep 3, 2025
    What causes low signal due to temperature in Metso Automation Measuring Instruments?
    • J
      Jennifer McintyreSep 3, 2025
      A substantial drop in process temperature may attenuate the signal level below the low limit set for the self-diagnostics. The signal level can be increased by performing a new start-up (section 6.A) at the new, higher signal level.
  • O
    obrienjohnnySep 7, 2025
    What causes a reference channel fault in metso automation kajaaniMCAi Measuring Instruments?
    • L
      Lisa WalkerSep 7, 2025
      This fault in Metso Automation Measuring Instruments is always caused by the Electronics Unit. Replace the Electronics Unit and perform a new start-up as instructed in section 6.A or in chapter 12. (HART communicator).

Summary

Caution; Warning

2.C. Sensor Electronics

2.C.1. Reset-Abort Procedure

Procedure to erase configurations and initialize device to system defaults.

4. Start-up

4.E. Configuration

Resets, configures initial settings, calibrates, and scales current outputs.

6. Configuration

6.A. Initial Configuration of Sensor

Steps for first-time sensor setup: language, sensor type, signal level.

6.A.2. Sensor Type Selection

Importance of selecting the correct sensor type for accurate calculation.

6.B. Current Output Scaling

6.B.1. Scaling Consistency Output

Configures 4-20mA output for consistency measurement.

6.B.2. Scaling Temperature Output

Configures 4-20mA output for temperature measurement.

6.B.3. Scaling Chemical Content Output

Configures 4-20mA output for chemical content measurement.

6.D. Reset-Abort

7. Calibration

7.A. First Calibration

Describes single-point calibration process using laboratory sample.

7.A.1. Sample Taking

Procedure for collecting process samples for calibration.

7.A.2. Entering Laboratory Result

Entering lab consistency and filler data for calibration.

7.B. Modifying the Calibration

9. Special Functions

9.B. Chemicals Compensation

Principle of compensating for process chemicals content effects.

9.B.1. Principle

Principle of compensating for process chemicals content effects.

9.B.2. Setting Chemicals Compensation

Steps to calibrate chemicals compensation using lab follow-up data.

9.B.3. Performing Chemical Compensation

How the chemical compensation graph is displayed and used.

9.C. Temperature Compensation

9.C.1. Determining the Correction Curve

Steps to create a temperature correction curve using lab follow-up data.

10. Self Diagnostics

10.A. Self-Diagnostics Functions

Functions for monitoring and testing the MCAi sensor.

10.B. Error Table

Displays error messages, date, time, and status of faults.

11. Troubleshooting & Service

11.A. Troubleshooting

General troubleshooting guide based on error detection.

11.B. Error Messages of Selfdiagnostics

11.C. Replacing Components

12. HART Communication

12.B.2. Calibration

Guidance on performing consistency calibration using HART.

12.C.1. Chemical Compensation

Compensating for chemical content variations affecting measurements.

12.C.2. Temperature Compensation Curve

Creating and applying correction curves for temperature effects on measurements.

metso automation kajaaniMCAi Specifications

General IconGeneral
Brandmetso automation
ModelkajaaniMCAi
CategoryMeasuring Instruments
LanguageEnglish