Instructions on how to adjust the time and temperature setpoint for events in the heating schedule.
How to temporarily override the programmed setpoint/temperature until the next scheduled event.
How to activate manual override, adjust setpoint, and exit manual mode.
Procedure to activate the child lock by pressing specific buttons simultaneously for 8 seconds.
Procedure to deactivate the child lock by pressing specific buttons simultaneously for 8 seconds.
Steps to activate the factory reset menu by pressing buttons and navigating options.
Explanation of 'no', 'SchE', and 'ALL' options for factory reset.
Instructions to enter and navigate the clock settings menu to adjust the time.
Steps to enter and navigate the day settings menu to change the day of the week.
How to enter and navigate schedule settings to choose or change the schedule type.
Explanation of OFF, 5-2, 6-1, 1E4, 7E4, and 1E2 schedule types.
Steps to enter and navigate display settings to select data shown on LCD 1 and LCD 2.
Defines what 'Set', 'cLc', and '--' mean for LCD 1 display.
Defines what 'Set' and 'tP' mean for LCD 2 display.
How to enter and set the temperature setpoint for remote controlled operation.
How to enable or disable the 'Open window' function that stops heating for 30 minutes.
How to enable or disable the adaptive start function for automatic heating optimization.
How to enter and use the adjustment option to calibrate the measured room temperature.
How to enter and choose temperature display as Celsius or a numerical value.
Procedure to enter settings and view the thermostat's software version.
How to view actual measured floor temperature (-FEP) and room temperature (-rEP).
How to enter and change the power limit setting for time-limited heating regulation.
How to enter and change the duration of heating periods via PWM settings.
Explanation of 'Off', 'On', and 'Aut' regulation types for PWM.
How to set minimum (FLLO) and maximum (FLH) temperature limits for the floor.
How to set minimum (ELLO) and maximum (ELH) temperature limits for thermostat operation.
How to select the sensor application (r, rE, rF, C, F) controlling the heating system.
Details on internal room, external room, floor sensor, and regulator modes.
Procedure to save changes and exit the menu, returning to the main screen.
List and explanation of error codes (E0, E1, E2, E5) and their meanings.
Information on how to get support for the thermostat from installer or place of purchase.
| Type | Electronic thermostat |
|---|---|
| Accuracy | ±0.5°C |
| Weight | 150g |
| Sensor Type | NTC |
| Mounting | Wall Mounted |
| Dimensions | 86mm x 86mm |