PAGE 27
© 2021 OJ Electronics A/S
Temperature limits (tLLo, tLhi)
These settings allow you to set the minimum and
maximum temperature that the thermostat can operate
inbetween.
Operating temperatures:
Temperature limit low (
tLLo) can be used to secure that
the temperature setpoint is unable to be set below a
specific value. Can be set between 0 and 40°C.
Temperature limit high (
tLHi) can be used to secure
that the temperature setpoint is unable to be set above a
specfic value. Can be set between 0 and 40°C.
Note: If the maximum temperature limit is set too high,
sensitive floor types may be permanently damaged.
REMOTE
Access the temperature limit settings:
• Press ”
”for 3 seconds to enter the settings.
• Scroll through the settings until either
tLLo
(temperature limit low) or
tLHi (temperature limit high)
appears on the display.
• Press ”
”to enter either tLLo or tLHi.
• Use ”” or ”” to adjust the temperature limits.
• Return to the settings with ”
”.
Menu structure:
tLLo: 0...40°C
tLHi: 0...40°C