PAGE 23
© 2021 OJ Electronics A/S
Power limit (P Li ) 2/2
Enter 6 minutes in the power limit menu in order to reduce
the heating by 10%.
Equation to calculate number of minutes that could
be entered in the power limit menu - when an average
heating eect is desired:
Average desired heating eect per m
2
Floor heating element output per m
2
(
1-
( )
)
∗ 60 min.
Note:
If the result of the equation is negative then nothing
should be entered.
The function is factory set to 0 minutes but can be set to
values between 0-30 minutes in steps of 1 minute.
Menu structure:
PLi: 0...30min
REMOTE