Specifications
n LANGbE192.168.0.103
Note: The SyncServer's network ports require Category 5 (or better) network cable.
SysplexOut
Summary:The Sysplex Timer port outputs serial time strings for IBM mainframe Sysplex sys-
tems. The Sysplex Timer provides a common time reference across all the members of an IBM
Sysplex. The Sysplex Timer is a key component when systems on multiple CPCs share access to
the same data. Also see TIMING - Sysplex (on page 64).
Description:Sysplex Out is a male 9-pin D connector mounted on the rear chassis that transmits
Time of Day (TOD) with carriage return on time to an attached Sysplex-compatible device. Con-
figured as DTE (Data Terminal Equipment). Configurable via the Web interface. Sysplex typ-
ically uses a "null-modem" serial cable (not supplied) for interconnection with other Sysplex
equipment.
Connector:male 9-pin (Sysplex Out)
Data Rates:9600 bps
Parity:Even, Odd, or None
Data Bits:8
Stop Bits:1
Pin Assignment:
n 1N/C
n 2Rx
n 3Tx
n 4N/C
n 5GND
n 6N/C
n 7RTS
n 8CTS
n 9N/C
Format:IBM 9037 Sysplex Timer (First Protocol)
Level:RS-232
Accuracy:<10 mS RMS
Phasing:Carriage return on-time marker
Control:Manual or Automatic start/stop, parity setting, flywheel quality character
String:<SOH>DDD:HH:MM:SSQ<CR><LF>
Where:
n <SOH>Start of Header
n DDDDay
n :Colon separator
n HHHours
n MMMinutes
n SSSeconds
n QTime Quality