EasyManua.ls Logo

Microsemi SyncServer S350 - Halting the SyncServer

Microsemi SyncServer S350
210 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Status LEDs
Status LEDs
The four tricolor LEDs provide the following status information:
Red Orange Green Dark
Sync
SyncServer is
not synchronized
to a
reference.
NTP Stratum 16.
SyncServer is syn-
chronized to a remote
NTP server.
NTP Stratum 2-15.
SyncServer is synchronized to
an Input Reference or the
modem
1
.
NTP Stratum 1.
Power off.
Network
Link failure on the
LAN1.
Link failure on the LAN2,
LAN3, or LANGBE.
All configured ports operational. Power off.
NTP
>7000 NTP pack-
ets per second.
> 5000 packets per
second.
NTP activity within the last
second.
No NTP
activity in
the last
second.
Alarm
Major Alarm. Minor Alarm. No Current/Enabled Alarms. Power off.
Also see Stratum (on page 202).
Halting the SyncServer
Microsemi recommends shutting the operating system down before removing the power.
Using the keypad/display interface:
1.
Press the MENU button.
2.
Select 3) Sys Control.
3.
Select 2) Shutdown.
4.
Press the ENTER button.
5. When the display shows "System Stopped - OK to Turn Power Off Now!" turn the power
off.
Or, using the web interface:
1.
Go to the SERVICES - Startup page.
2.
Select Halt and click the APPLY button.
3. Wait approximately 30 seconds before removing power.
1
The SyncServer S350i does not include a modem.
997-01520-02 Rev. F1.......................................................................... Page 15

Table of Contents