EasyManua.ls Logo

Mid-tech ARC 6000 - Page 41

Mid-tech ARC 6000
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-3
98-05012
R3
ARC-6000
Check cables, from Flow
Control port on back of
console, to valve for bad
connections, abrasions, and
pinched or broken wires.
Check for blown fuses
Check cables, from Boom
Interface port on back of
console, to valves for bad
connections, abrasions, and
pinched or broken wires.
Check for blockage of the
flow meter rotor.
Check cables, from Flow
Control port on back of
console, to flowmeter for bad
connections, abrasions, and
pinched or broken wires.
Contact your MID-TECH
dealer if you see this message
on an ARC controller.
Check Flow Control
connections on the back of
the console. Secure if loose.
Check in-line fuse (optional)
near positive battery connec-
tion.
Check valve control signals.
Check cables, from Flow
Control port on back of
console, to valve, for bad
connections, abrasions, and
pinched or broken wires.
Consult Chapter 2 for the
correct switch sequence.
Err 3
Pump L
(Cont.)
Err 4
Err 5
Pump L
Err
Boom valves are not opening.
Flow in the product line.
Not a diagnostic function in
the ARC.
Application rate is exceeding
the target rate by 15%. Valve
is not responding.
Incorrect switch sequence is
selected on the console.