5-4
ARC-6000
98-05012
R3
Err E
OFLO
Err L
Err C, n,
hook (back-
ward 7)
Hold down the decrease
switch until the alarm stops.
Check for any constants that
may have been set to zero
and re-enter the correct
values. (See Chapter 2)
Hold down the decrease
switch until the display re-
sets to zero.
Establish good ground and
battery connections. This is
the most common fault when
system is acting erratically.
Check and service or replace
the vehicle battery.
Check and service or replace
the vehicle alternator/voltage
regulator.
A momentary appearance,
followed by no other
problems, can be safely
ignored. If messages occur
frequently during operation,
or come on and stay on,
contact your dealer for
further assistance.
Memory error.
This is often the result of a
poor battery connection.
Value to be displayed on
console exceeds the maximum
displayable size.
The vehicle electrical system
voltage has fallen below about
10.0 VDC.
Internal Diagnostics.