The position of barycenter for different units can be seen in the picture below.
07
The hook and barycenter of
the unit should be on a line
in vertical direction to
prevent improper inclination
Make the rope go through
the lifting holes from both
the right and left sides in the
wooden collet
≥1000mm
To avoid injury, do not touch the air inlet or aluminum fins of the unit.
Do not use the grips in the fan grills to avoid damage.
The unit is top heavy! Prevent the unit from falling due to improper inclination during handling.
CAUTION
5 IMPORTANT INFORMATION FOR THE REFRIGERANT
This product has the fluorinated gas, which is forbidden to release to air.
Refrigerant type: R32; Volume of GWP: 675.
GWP=Global Warming Potential
Factory charged refrigerant volume in the unit
Refrigerant/kg
Tonnes CO
2 equivalent
4kW
1.40 0.95
6kW
1.40 0.95
8kW
1.40 0.95
12kW
1.75
1.18
14kW
1.75
1.18
16kW
1.75
1.18
Model
4/6 kW (unit:mm)
A
A
C
B
C
A
B
A
8/10/12/14/16 kW (unit:mm)
10kW
1.40
0.95
Model AA
1 phase 4/6kW
1 phase 8/10kW
B C
1 phase 12/14/16kW
3 phase 12/14/16kW
370 540 190
410 580 280
370 605 245
280 605 245