37
Voltage
(V)
Hz Min.
(V)
Max.
(V)
MCA
(A)
TOCA
(A)
MFA
(A)
MSC
(A)
RLA
(A)
KW FLA
(A)
Outdoor Unit Power Current Compressor OFM
1
1
1
1
14 18
-
13.50
0.10
0.50
264 25220-240        50 198
-
14.50
0.17
1.5016
19264 25220-240        50 198
-
17 19
15.50
0.17
1.50
264198 25220-240        50
12 25
-
0.10
0.50220-240        50
198 264 18
11.50
System
6kW
4kW
8kW
10kW
-
25 30
23.50
0.17
1.50
264198 35220-240        5012kW
-
26 30
24.50
0.17
1.50
264198 35220-240        5014kW
1
-
27 30
25.50
0.17
1.50
264198 35220-240        5016kW
-
10 14
9.15
0.17
1.50
456342 16380-415        5012kW 3-PH
1
-
11 14
10.15
0.17
1.50
456342 16380-415        5014kW 3-PH
-
12 14
11.15
0.17
1.50
456342 16380-415        5016kW 3-PH
Table 9-2
 Rated current 
of appliance:(A) 
 
Nominal cross-sectional area (mm  ) 
 
 
 
 
 
 
 
2
 
Flexible cords Cable for fixed wiring
Table 9-1
   ≤3                 0.5   and  0.75               1     and  2.5
>3     and  ≤6                 0.75 and  1                    1     and  2.5
>6     and  ≤10               1      and  1.5                 1     and  2.5
>10   and  ≤16               1.5   and  2.5                 1.5  and  4
>16   and  ≤25               2.5   and  4                    2.5  and  6
>25   and  ≤32               4      and  6                    4     and  10
>32   and  ≤50               6      and  10                  6     and  16
>50   and  ≤63               10    and  16                  10   and  25
1-phase 4-16kW stadard and 3-phase 12-16kW standard 
Voltage
(V)
Hz Min.
(V)
Max.
(V)
MCA
(A)
TOCA
(A)
MFA
(A)
MSC
(A)
RLA
(A)
KW FLA
(A)
Outdoor Unit Power Current Compressor OFM
1
1
1
1
27 31
-
13.50
0.10
0.50
264 38220-240        50 198
-
14.50
0.17
1.5029
32264 38220-240        50 198
-
30 32
15.50
0.17
1.50
264198 38220-240        50
25 38
-
0.10
0.50220-240        50
198 264 31
11.50
System
6kW
4kW
8kW
10kW
-
38 43
23.50
0.17
1.50
264198 48220-240        5012kW
-
39 43
24.50
0.17
1.50
264198 48220-240        5014kW
1
-
40 43
25.50
0.17
1.50
264198 48220-240        5016kW
-
23 27
9.15
0.17
1.50
456342 29380-415        5012kW 3-PH
1
-
24 27
10.15
0.17
1.50
456342 29380-415        5014kW 3-PH
-
25 27
11.15
0.17
1.50
456342 29380-415        5016kW 3-PH
1-phase 4-16kW and 3-phase 12-16kW standard with backup heater 3kW 
Voltage
(V)
Hz Min.
(V)
Max.
(V)
MCA
(A)
TOCA
(A)
MFA
(A)
MSC
(A)
RLA
(A)
KW FLA
(A)
Outdoor Unit Power Current Compressor OFM
1
1
1
-
14.50
0.17
1.5029
32264 38220-240        50 198
-
30 32
15.50
0.17
1.50
264198 38220-240        50
System
8kW
10kW
-
38 43
23.50
0.17
1.50
264198 48220-240        5012kW
-
39 43
24.50
0.17
1.50
264198 48220-240        5014kW
1
-
40 43
25.50
0.17
1.50
264198 48220-240        5016kW
-
23 27
9.15
0.17
1.50
456342 29380-415        5012kW 3-PH
1
-
24 27
10.15
0.17
1.50
456342 29380-415        5014kW 3-PH
-
25 27
11.15
0.17
1.50
456342 29380-415        5016kW 3-PH
1-phase 8-16kW and 3-phase 12-16kW standard with backup heater 9kW