Optional modules:
63
When a dispenser pump is selected, the following will appear in the
display:
Dispenser calibration
Dispenser pump 1
V: 100 ml
0/1
0st: P: No
Tip: The dispensing amount can be set from 0 to 9999ml in 1ml in-
crements.
Press multifunction button0/1.
The dispensing hose will fill up.
Stop the process by pressing button0/1.
Run the hose of the dispenser pump that is being checked upwards
into a measuring vessel.
Irritant agents.
Skin and eye irritation.
Avoid contact with skin and eyes, wear protective clothing.
Return to the main menu by pressing "Back".
Dispenser calibration
Main menu
Dispenser pump 1
Dispenser pump 2
Select a dispenser pump.
Dispenser calibration
Dispenser pump 1
0/1
0 st:
P: No
V: 100 ml
Press multifunction button0/1.
Stop the pump by pressing button0/1, or the pump will stop auto-
matically after 60seconds.
Measure the required amount in the measuring vessel.
Dispenser calibration
Dispenser pump 1
0/1
30 st: P: 200 ml/minV: 100 ml
Enter the amount measured in field"V:".
The throughputP is calculated in ml/min. by the controls.
Press the "Save" button.
The measured value is assigned to the pump.
Reattach the hose.