Washing without dispenser compartment
25
Dispenser calibration
Dispensing calibration is used to measure the throughput of individual
dispensing pumps.
To go directly to
"dispenser calib-
ration" when the
machine is
switched off:
Press and hold multifunction button2 and switch the machine on
with Power on.
Options:
– Dispenser pump 1to13
Select a dispenser pump.
When a dispenser pump is selected, the following will appear in the
display:
Tip: The dispensing amount can be set from 0 to 9999ml in 1ml in-
crements.
Press multifunction button0/1.
The dispensing hose will fill up.
Stop the process by pressing button0/1.
Run the hose of the dispenser pump that is being checked upwards
into a measuring vessel.
Irritant agents.
Skin and eye irritation.
Avoid contact with skin and eyes, wear protective clothing.
Return to the main menu by pressing "Back".