Installation and connection
80
Unscrew the screws at the bottom of the back panel and remove
the panel.
Loosen the hexagon screws to remove the transport safety panels.
Retain the transport safety panels. They need to be refitted should
the machine ever need to be moved again.
Plumbing
Water pressure (flow pressure) of a minimum 1bar (100kPa) / max-
imum 10bar (1000kPa) is required to guarantee problem free pro-
gramme operation.
The machine must be connected to the water supply using the inlet
hoses provided.
Hoses must be replaced with hoses tested for a burst pressure of at
least 70bar (7000kPa) and for water temperatures of a minimum of
90°C.
This also applies for associated connection fittings. Miele original re-
placement parts fulfil these requirements.
Tip: The hot water supply must not exceed a maximum temperature
of 60°C.
Connection to the cold water supply
The Y-piece is supplied with the machine.