OM-286504 Page 47
F
Complete Parts List is available at www.MillerWelds.com
Trouble Remedy
Erratic power output at AC
receptacles.
Check fuel level.
Check engine speed, and adjust if necessary (see Section 8-7 or 8-8).
Check receptacle wiring and connections.
Have Factory Authorized Service Agent check brushes and slip rings.
C. Engine Troubleshooting
Trouble Remedy
Engine will not crank.
Check fuse F6, and replace if open (see Section 8-5).
Check battery voltage.
Check battery connections and tighten if necessary.
Check plug PLG4 and plug PLG8 connections.
Have Factory Authorized Service Agent check Engine Control switch S2.
Engine will not start.
Check fuel level.
Check battery voltage.
Check battery connections and tighten if necessary.
Check oil level (see Section 5-4).
Check low oil pressure shutdown switch.
Have Factory Authorized Service Agent check fuel shutoff solenoid FS1 (carbureted engine only).
Check fuses F4 and F5 on EFI engines, and replace if open.
Verify e-choke is operating. If not, contact engine service center.
Engine starts but stops when Engine
Control switch returns to Run position.
Check oil level.
Check and refill crankcase with proper viscosity oil for operating temperature, if necessary.
Check low oil pressure shutdown switch.
Engine stopped during normal
operation.
Check fuel level.
Replace fuel filter(s) (see Section 8-6).
Check oil level (see Section 5-4).
Check low oil pressure shutdown switch.
Periodically recharge battery (approximately every 3 months).
Replace battery.
Check voltage regulator and connections according to engine manual.
Have Factory Authorized Service Agent check fuel shutoff solenoid FS1 (carbureted engine only).
Battery discharges between uses.
Clean battery, terminals, and posts with baking soda and water solution; rinse with clear water.
Periodically recharge battery (approximately every 3 months).
Replace battery.
Check voltage regulator and connections according to engine manual.
Engine idles but does not come up to
weld speed.
Have Factory Authorized Service Agent check fuel gauge/hourmeter/idle control, and current trans-
former CT1.
Unstable or sluggish engine speeds.
Readjust throttle linkage if necessary. Check throttle solenoid TS1 for smooth operation.
Check oil level. Oil level should not exceed Full mark on dipstick. Fuel pump will operate erratically if
crankcase is overfilled.
Tune-up engine according to engine manual.
Engine does not return to idle speed.
Remove weld and generator power loads.
Check throttle linkage for smooth, non-binding operation.
Have Factory Authorized Service Agent check idle module, current transformer CT1, Engine Control
switch S2, and throttle solenoid TS1.
During operation in near freezing tem-
peratures, engine starts and goes to
idle but stalls after a few minutes.
Treat fuel with isopropyl alcohol de-icer product.
Place Engine Control switch in the Run position until unit has been in operation and loaded for a peri-
od of time.
During operation in severe cold weath-
er, engine starts and goes to idle but
stalls after a few minutes.
Install engine manufacturer's kit for cold-weather operation.